Appliances Renovation

Electrical Appliance Not Always Electric, Small Appliance is a BIG Business

Why my Electric Washer (Washing Machine) Stops in Cycle, what is wrong and how to fix it?

Specific failure symptoms include: 1) The washer won’t complete the wash or spin cycle. 2) The washer has a burning smell during the wash and spin cycle. 3) The washer leaves water in the tub at the end of the cycle.

Check the washer power cord for a possible loose connection at the wall plug receptacle.

Check to see if the wall receptacle is defective or has burned or oxidized contacts. If so, the repair should be made by a licensed electrician. Read the rest of this entry »

Washer Won’t Start in Cycle (Get Washing Machine Fixed)

Specific failure symptoms include: 1) When the washer is turned ON, nothing happens. 2) When the washer is turned ON you hear a faint “buzz.”

To find the cause of this problem, first check to be sure that the washer is plugged in a working power source.

Check Washer Receptacle

Make a line voltage check at the washer receptacle to determine if the problem is a faulty power receptacle or a problem within the washer. Make a voltage line check by setting the volt/ohmmeter on the 150 A/C scale and placing the probes in the holes of the wall receptacle. The meter should read 110-125 volts. Read the rest of this entry »

Home Appliance Timber Dryer does not Heat, how to fix? part 3

Check Cycling Thermostats

Next, check the dryer cycling thermostats as the possible cause for no heat in the dryer. The types of thermostats most commonly used in dryers (gas or electric), are the bimetal fixedand adjustable thermostats. Their primary function is to break the circuit to the gas main burner or the heating element when a certain temperature has been attained in the dryer drum. You can easily check these thermostats by removing one lead from the suspected thermostat. Set the volt/ohmmeter on the RX-1 scale. Place one probe of the volt/- ohmmeter on each terminal of the thermostat. You should see a continuity reading on the volt/- ohmmeter scale of approximately 0 ohms, or full- meter deflection. If the thermostat does not show continuity, replace the defective thermostat to restore the dryer to proper operating order. Read the rest of this entry »

Home Appliance Timber Dryer does not Heat, how to fix? part 1

Specific failure symptoms include: 1) Clothes are not dry at end of cycle. 2) The dryer timer assembly is not advancing in the cycle properly.

To find the cause of the problem, first move the dryer out from the wall and remove the vent hose. With the dryer running, place your hand on the dryer exhaust duct to determine if there is any hot air being discharged. If the air is cold, you will have to make a line voltage check at the dryer receptacle to determine whether full 220-to-240-volt power is available. Read the rest of this entry »

Electronic Timber Dryers Stops in Cycle

This failure is normally attributed to a loss of electrical power or an electrical overload.

To find the cause of the problem, move the dryer out from the wall and unplug the dryer power cord from dryer wall receptacle. Make a voltage check with the volt/ohmmeter to determine if there is electrical power available to the dryer receptacle or to the dryer power cord.

Using Test Equipment

To avoid incorrect readings when using the volt/ohmmeter, always “zero” the ohmmeter before making continuity checks. See operating instructions that came with your volt/ohmmeter. Read the rest of this entry »

My Electrical Appliance Timber Dryers does not Start in Cycle, how to fix it (check point)

An obvious failure symptom is when you select a drying cycle and attempt to start the dryer, but it does not run. To find the cause of the problem, move the dryer out from its position and unplug the power cord.

If line voltage is indicated on the volt/- ohmmeter, check the dryer power cord as possible cause of the problem.

Using Test Equipment

To avoid any incorrect readings when using the volt/ohmmeter, always “zero” the ohmmeter before making continuity checks on components. Read the rest of this entry »

Timber Dryer is too Noisy, how to fix it?

Specific problems include: 1) The clothes dryer has excessive noise while running. 2) The clothes dryer stops in cycle. 3) The clothes are extremely damp when removed from the dryer drum at end of cycle.

All of the above symptoms are related to mechanical problems which develop from years of use.

Check Timber Dryer Drum Belt

Check the clothes dryer drum belt for excessive play or a stretched condition. A drum belt that is excessively stretched will cause the idler pulley to bang against the drum, resulting in excessive noise. In order to restore the dryer to proper operating order, you will have to replace the drive belt. Read the rest of this entry »

Fridge does not run, Interior Light Comes on (Check Point) continue…

Check Start Capacitor

There are three types of failures that are associated with the Fridge start capacitor. These failures are a defective capacitor. an open filament capacitor, and a grounded capacitor. You can check each of the above failures with the volt/ohmmeter. First, unplug the Fridge power cord. Using hand tools, remove the screws that secure the Fridge back and remove the starting capacitor from the compressor starting package. Look for traces of oil on or around the capacitor. If oil is present, the capacitor is defective.

CAUTION: A charged capacitor is extremely dangerous. A capacitor that has been removed from the compressor starting package will hold a charge indefinitely, even when not in use. If you touch the terminals of a charged capacitor, the built-up voltage could give a high-voltage shock that could be fatal. A flat-blade screwdriver across the terminals should be used to discharge a capacitor. Read the rest of this entry »

Fridge runs Continuously, Cabinet Warm, fix Household Appliance by yourself (check points) continue…

Check Evaporator Fan Motor

You can check the evaporator fan motor by removing the plastic breaker strips on the left- and right-hand sides of the freezer section of the fridge.

NOTE: When removing the plastic breaker strips, it is recommended that they be pre-heated using a 40-to-60-watt light bulb. The light bulb is applied to each breaker strip for 5 to 7 minutes, to warm the pieces and make them more pliable and less subject to breakage. Read the rest of this entry »

Fridge Frost Build-up in Freezer, how to Fix it? (Check Points)

Specific failure symptoms include: 1) Frost build-up on back wall in freezer section of Fridge. 2) Fridge ice maker not making ice. 3) Food not remaining at the desired temperature in both the Fridge and freezer sections.

When the Fridge starts to build up frost in the freezer section, you can assume that something is preventing the Fridge from going into the defrost cycle. You will have to check the components of the defrost circuit. Move the Fridge out from the wall and unplug the Fridge power cord. Check the components in the order listed below. Read the rest of this entry »