The earth path of an appliance can be checked easily using a simple test meter. Remember, path of low resistance is required from all items within a appliance that are linked into the earth path via the yellow and green cable.
The earth path of an appliance from its exposed metal parts to the earth pin of the plug should be a maximum of 1 ohm (BS3456).
Checking the earth path of a socket requires an earth loop test meter which needs to be operated correctly. This is an expensive item and, moreover, problems may be encountered with distribution boards fitted with an RCD. It is, therefore, advisable to have these tests done by a qualified electrical contractor. Read the rest of this entry »