Socket-outlets situated off the main route of the cable do not have to be connected to the actual ring cable. Instead they are usually supplied from spur cables branching off the ring. These spurs are wired in the same size cable as that used for the ring.
Fixed appliances which may be connected to a ring circuit include skirting heaters, wall heaters, small water heaters and any non-portable electrical appliances having individual loadings of not more than 3000 W(13 A approx.). Read the rest of this entry »
Electric heating of water can be carried out in a variety of ways. These include small capacity heaters fitted above the sink, instantaneous sink heaters or immersion heaters in the hot water tank.
Small storage water heaters fitted over the sink or washbasin having capacities of up to about 3 gallons and electrical loadings of 1 to 3 kW are usually supplied from the ring circuit by means of a spur. Except in a bathroom, the outlet can be a fused plug and switched socket-outlet, preferably with neon indicator. Read the rest of this entry »