Specific failure symptoms include: 1) The clothes dryer is running longer than normal. 2) The clothes are extremely damp at the end of the drying cycle.
Although the problem could be that the automatic washer is not spinning your clothes properly, in most cases the problem is inadequate air movement in the dryer.
Before blaming the dryer, you should check the automatic washer. At the end of the spin cycle, open the washer lid and check to see if there is excess water left in the washer basket. Read the rest of this entry »
Specific problems include: 1) The clothes dryer has excessive noise while running. 2) The clothes dryer stops in cycle. 3) The clothes are extremely damp when removed from the dryer drum at end of cycle.
All of the above symptoms are related to mechanical problems which develop from years of use.
Check the clothes dryer drum belt for excessive play or a stretched condition. A drum belt that is excessively stretched will cause the idler pulley to bang against the drum, resulting in excessive noise. In order to restore the dryer to proper operating order, you will have to replace the drive belt. Read the rest of this entry »
Specific failure symptoms include: 1) Water collecting on shelves and food, and under crisper pans in the refrigerator section. 2) Water running down back wall of refrigerator. To find the cause of the problem, which is probably a defrost drain obstruction, unplug the refrigerator power cord and open the refrigerator door.
As a no-frost refrigerator enters the defrost cycle, a defrost heater is energized and melts the frost and ice that has accumulated on the evaporator coil between defrost cycles. Read the rest of this entry »
Next in line after the water supply valve is the water inlet valve, usually located at the back of the machine near the bottom. The role of the water inlet valve is to release supply water from the supply line so that it can enter the icemaker mold cavity. However, the valve’s internal components can eventually become worn out from the corrosive properties and algae in the water, and fail to supply water to the mold cavity. Check the water inlet valve to see if it is electrically releasing the water on command to the mold cavity. Read the rest of this entry »